ALSA: oxygen: fix analog capture on Claro halo cards
On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input. Using the default first input, which isn't connected
to anything, would result in silence.
Signed-off-by: Erik J. Staab <ejs@insightbb.com>
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Cc: <stable@kernel.org>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
diff --git a/sound/pci/oxygen/oxygen.c b/sound/pci/oxygen/oxygen.c
index 289cb4d..6c0a11a 100644
--- a/sound/pci/oxygen/oxygen.c
+++ b/sound/pci/oxygen/oxygen.c
@@ -543,6 +543,10 @@
chip->model.suspend = claro_suspend;
chip->model.resume = claro_resume;
chip->model.set_adc_params = set_ak5385_params;
+ chip->model.device_config = PLAYBACK_0_TO_I2S |
+ PLAYBACK_1_TO_SPDIF |
+ CAPTURE_0_FROM_I2S_2 |
+ CAPTURE_1_FROM_SPDIF;
break;
}
if (id->driver_data == MODEL_MERIDIAN ||