IB/addr: Pass network namespace as a parameter

Add network namespace support to the ib_addr module. For that, all the
address resolution and matching should be done using the appropriate
namespace instead of init_net.

This is achieved by:

1. Adding an explicit network namespace argument to exported function that
   require a namespace.
2. Saving the namespace in the rdma_addr_client structure.
3. Using it when calling networking functions.

In order to preserve the behavior of calling modules, &init_net is
passed as the parameter in calls from other modules. This is modified as
namespace support is added on more levels.

Signed-off-by: Haggai Eran <haggaie@mellanox.com>
Signed-off-by: Yotam Kenneth <yotamke@mellanox.com>
Signed-off-by: Shachar Raindel <raindel@mellanox.com>
Signed-off-by: Guy Shapiro <guysh@mellanox.com>
Signed-off-by: Doug Ledford <dledford@redhat.com>
diff --git a/drivers/infiniband/core/addr.c b/drivers/infiniband/core/addr.c
index d3c42b3..34b1ada 100644
--- a/drivers/infiniband/core/addr.c
+++ b/drivers/infiniband/core/addr.c
@@ -128,7 +128,7 @@
 	int ret = -EADDRNOTAVAIL;
 
 	if (dev_addr->bound_dev_if) {
-		dev = dev_get_by_index(&init_net, dev_addr->bound_dev_if);
+		dev = dev_get_by_index(dev_addr->net, dev_addr->bound_dev_if);
 		if (!dev)
 			return -ENODEV;
 		ret = rdma_copy_addr(dev_addr, dev, NULL);
@@ -138,7 +138,7 @@
 
 	switch (addr->sa_family) {
 	case AF_INET:
-		dev = ip_dev_find(&init_net,
+		dev = ip_dev_find(dev_addr->net,
 			((struct sockaddr_in *) addr)->sin_addr.s_addr);
 
 		if (!dev)
@@ -149,12 +149,11 @@
 			*vlan_id = rdma_vlan_dev_vlan_id(dev);
 		dev_put(dev);
 		break;
-
 #if IS_ENABLED(CONFIG_IPV6)
 	case AF_INET6:
 		rcu_read_lock();
-		for_each_netdev_rcu(&init_net, dev) {
-			if (ipv6_chk_addr(&init_net,
+		for_each_netdev_rcu(dev_addr->net, dev) {
+			if (ipv6_chk_addr(dev_addr->net,
 					  &((struct sockaddr_in6 *) addr)->sin6_addr,
 					  dev, 1)) {
 				ret = rdma_copy_addr(dev_addr, dev, NULL);
@@ -236,7 +235,7 @@
 	fl4.daddr = dst_ip;
 	fl4.saddr = src_ip;
 	fl4.flowi4_oif = addr->bound_dev_if;
-	rt = ip_route_output_key(&init_net, &fl4);
+	rt = ip_route_output_key(addr->net, &fl4);
 	if (IS_ERR(rt)) {
 		ret = PTR_ERR(rt);
 		goto out;
@@ -278,12 +277,12 @@
 	fl6.saddr = src_in->sin6_addr;
 	fl6.flowi6_oif = addr->bound_dev_if;
 
-	dst = ip6_route_output(&init_net, NULL, &fl6);
+	dst = ip6_route_output(addr->net, NULL, &fl6);
 	if ((ret = dst->error))
 		goto put;
 
 	if (ipv6_addr_any(&fl6.saddr)) {
-		ret = ipv6_dev_get_saddr(&init_net, ip6_dst_idev(dst)->dev,
+		ret = ipv6_dev_get_saddr(addr->net, ip6_dst_idev(dst)->dev,
 					 &fl6.daddr, 0, &fl6.saddr);
 		if (ret)
 			goto put;
@@ -477,6 +476,7 @@
 
 	memset(&dev_addr, 0, sizeof(dev_addr));
 	dev_addr.bound_dev_if = if_index;
+	dev_addr.net = &init_net;
 
 	ctx.addr = &dev_addr;
 	init_completion(&ctx.comp);
@@ -511,6 +511,7 @@
 	rdma_gid2ip(&gid_addr._sockaddr, sgid);
 
 	memset(&dev_addr, 0, sizeof(dev_addr));
+	dev_addr.net = &init_net;
 	ret = rdma_translate_ip(&gid_addr._sockaddr, &dev_addr, vlan_id);
 	if (ret)
 		return ret;