hwmon: (adt7470) Fix writes to temperature limit registers
Temperature limit registers are signed. Limits therefore need
to be clamped to (-128, 127) degrees C and not to (0, 255)
degrees C.
Without this fix, writing a limit of 128 degrees C sets the
actual limit to -128 degrees C.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Cc: stable@vger.kernel.org
Reviewed-by: Axel Lin <axel.lin@ingics.com>
diff --git a/drivers/hwmon/adt7470.c b/drivers/hwmon/adt7470.c
index 0f4dea5..9ee3913 100644
--- a/drivers/hwmon/adt7470.c
+++ b/drivers/hwmon/adt7470.c
@@ -515,7 +515,7 @@
return -EINVAL;
temp = DIV_ROUND_CLOSEST(temp, 1000);
- temp = clamp_val(temp, 0, 255);
+ temp = clamp_val(temp, -128, 127);
mutex_lock(&data->lock);
data->temp_min[attr->index] = temp;
@@ -549,7 +549,7 @@
return -EINVAL;
temp = DIV_ROUND_CLOSEST(temp, 1000);
- temp = clamp_val(temp, 0, 255);
+ temp = clamp_val(temp, -128, 127);
mutex_lock(&data->lock);
data->temp_max[attr->index] = temp;
@@ -826,7 +826,7 @@
return -EINVAL;
temp = DIV_ROUND_CLOSEST(temp, 1000);
- temp = clamp_val(temp, 0, 255);
+ temp = clamp_val(temp, -128, 127);
mutex_lock(&data->lock);
data->pwm_tmin[attr->index] = temp;