| # Copyright (c) 2006-2007 The Regents of The University of Michigan | |
| # Copyright (c) 2009 Advanced Micro Devices, Inc. | |
| # All rights reserved. | |
| # | |
| # Redistribution and use in source and binary forms, with or without | |
| # modification, are permitted provided that the following conditions are | |
| # met: redistributions of source code must retain the above copyright | |
| # notice, this list of conditions and the following disclaimer; | |
| # redistributions in binary form must reproduce the above copyright | |
| # notice, this list of conditions and the following disclaimer in the | |
| # documentation and/or other materials provided with the distribution; | |
| # neither the name of the copyright holders nor the names of its | |
| # contributors may be used to endorse or promote products derived from | |
| # this software without specific prior written permission. | |
| # | |
| # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS | |
| # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT | |
| # LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR | |
| # A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT | |
| # OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, | |
| # SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT | |
| # LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, | |
| # DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY | |
| # THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT | |
| # (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE | |
| # OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. | |
| # | |
| # Authors: Ron Dreslinski | |
| # Brad Beckmann | |
| import m5 | |
| from m5.objects import * | |
| from m5.defines import buildEnv | |
| from m5.util import addToPath | |
| import os, optparse, sys | |
| addToPath('../') | |
| from common import Options | |
| from ruby import Ruby | |
| # Get paths we might need. It's expected this file is in m5/configs/example. | |
| config_path = os.path.dirname(os.path.abspath(__file__)) | |
| config_root = os.path.dirname(config_path) | |
| m5_root = os.path.dirname(config_root) | |
| parser = optparse.OptionParser() | |
| Options.addNoISAOptions(parser) | |
| parser.add_option("--maxloads", metavar="N", default=100, | |
| help="Stop after N loads") | |
| parser.add_option("-f", "--wakeup_freq", metavar="N", default=10, | |
| help="Wakeup every N cycles") | |
| # | |
| # Add the ruby specific and protocol specific options | |
| # | |
| Ruby.define_options(parser) | |
| execfile(os.path.join(config_root, "common", "Options.py")) | |
| (options, args) = parser.parse_args() | |
| # | |
| # Set the default cache size and associativity to be very small to encourage | |
| # races between requests and writebacks. | |
| # | |
| options.l1d_size="256B" | |
| options.l1i_size="256B" | |
| options.l2_size="512B" | |
| options.l3_size="1kB" | |
| options.l1d_assoc=2 | |
| options.l1i_assoc=2 | |
| options.l2_assoc=2 | |
| options.l3_assoc=2 | |
| if args: | |
| print "Error: script doesn't take any positional arguments" | |
| sys.exit(1) | |
| # | |
| # Create the ruby random tester | |
| # | |
| # Check the protocol | |
| check_flush = False | |
| if buildEnv['PROTOCOL'] == 'MOESI_hammer': | |
| check_flush = True | |
| tester = RubyTester(check_flush = check_flush, | |
| checks_to_complete = options.maxloads, | |
| wakeup_frequency = options.wakeup_freq) | |
| # | |
| # Create the M5 system. Note that the Memory Object isn't | |
| # actually used by the rubytester, but is included to support the | |
| # M5 memory size == Ruby memory size checks | |
| # | |
| system = System(cpu = tester, mem_ranges = [AddrRange(options.mem_size)]) | |
| # Create a top-level voltage domain and clock domain | |
| system.voltage_domain = VoltageDomain(voltage = options.sys_voltage) | |
| system.clk_domain = SrcClockDomain(clock = options.sys_clock, | |
| voltage_domain = system.voltage_domain) | |
| Ruby.create_system(options, False, system) | |
| # Create a seperate clock domain for Ruby | |
| system.ruby.clk_domain = SrcClockDomain(clock = options.ruby_clock, | |
| voltage_domain = system.voltage_domain) | |
| assert(options.num_cpus == len(system.ruby._cpu_ports)) | |
| tester.num_cpus = len(system.ruby._cpu_ports) | |
| # | |
| # The tester is most effective when randomization is turned on and | |
| # artifical delay is randomly inserted on messages | |
| # | |
| system.ruby.randomization = True | |
| for ruby_port in system.ruby._cpu_ports: | |
| # | |
| # Tie the ruby tester ports to the ruby cpu read and write ports | |
| # | |
| if ruby_port.support_data_reqs and ruby_port.support_inst_reqs: | |
| tester.cpuInstDataPort = ruby_port.slave | |
| elif ruby_port.support_data_reqs: | |
| tester.cpuDataPort = ruby_port.slave | |
| elif ruby_port.support_inst_reqs: | |
| tester.cpuInstPort = ruby_port.slave | |
| # Do not automatically retry stalled Ruby requests | |
| ruby_port.no_retry_on_stall = True | |
| # | |
| # Tell each sequencer this is the ruby tester so that it | |
| # copies the subblock back to the checker | |
| # | |
| ruby_port.using_ruby_tester = True | |
| # ----------------------- | |
| # run simulation | |
| # ----------------------- | |
| root = Root( full_system = False, system = system ) | |
| root.system.mem_mode = 'timing' | |
| # Not much point in this being higher than the L1 latency | |
| m5.ticks.setGlobalFrequency('1ns') | |
| # instantiate configuration | |
| m5.instantiate() | |
| # simulate until program terminates | |
| exit_event = m5.simulate(options.abs_max_tick) | |
| print 'Exiting @ tick', m5.curTick(), 'because', exit_event.getCause() |