| * linux/drivers/thermal/cpu_cooling.c | |
| * | |
| * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) | |
| * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org> | |
| * | |
| * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| * This program is free software; you can redistribute it and/or modify | |
| * it under the terms of the GNU General Public License as published by | |
| * the Free Software Foundation; version 2 of the License. | |
| * | |
| * This program is distributed in the hope that it will be useful, but | |
| * WITHOUT ANY WARRANTY; without even the implied warranty of | |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU | |
| * General Public License for more details. | |
| * | |
| * You should have received a copy of the GNU General Public License along | |
| * with this program; if not, write to the Free Software Foundation, Inc., | |
| * 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA. | |
| * | |
| * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| */ | |
| #include <linux/module.h> | |
| #include <linux/thermal.h> | |
| #include <linux/cpufreq.h> | |
| #include <linux/err.h> | |
| #include <linux/slab.h> | |
| #include <linux/cpu.h> | |
| #include <linux/cpu_cooling.h> | |
| /** | |
| * struct cpufreq_cooling_device - data for cooling device with cpufreq | |
| * @id: unique integer value corresponding to each cpufreq_cooling_device | |
| * registered. | |
| * @cool_dev: thermal_cooling_device pointer to keep track of the | |
| * registered cooling device. | |
| * @cpufreq_state: integer value representing the current state of cpufreq | |
| * cooling devices. | |
| * @cpufreq_val: integer value representing the absolute value of the clipped | |
| * frequency. | |
| * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device. | |
| * | |
| * This structure is required for keeping information of each | |
| * cpufreq_cooling_device registered. In order to prevent corruption of this a | |
| * mutex lock cooling_cpufreq_lock is used. | |
| */ | |
| struct cpufreq_cooling_device { | |
| int id; | |
| struct thermal_cooling_device *cool_dev; | |
| unsigned int cpufreq_state; | |
| unsigned int cpufreq_val; | |
| struct cpumask allowed_cpus; | |
| }; | |
| static DEFINE_IDR(cpufreq_idr); | |
| static DEFINE_MUTEX(cooling_cpufreq_lock); | |
| static unsigned int cpufreq_dev_count; | |
| /* notify_table passes value to the CPUFREQ_ADJUST callback function. */ | |
| #define NOTIFY_INVALID NULL | |
| static struct cpufreq_cooling_device *notify_device; | |
| /** | |
| * get_idr - function to get a unique id. | |
| * @idr: struct idr * handle used to create a id. | |
| * @id: int * value generated by this function. | |
| * | |
| * This function will populate @id with an unique | |
| * id, using the idr API. | |
| * | |
| * Return: 0 on success, an error code on failure. | |
| */ | |
| static int get_idr(struct idr *idr, int *id) | |
| { | |
| int ret; | |
| mutex_lock(&cooling_cpufreq_lock); | |
| ret = idr_alloc(idr, NULL, 0, 0, GFP_KERNEL); | |
| mutex_unlock(&cooling_cpufreq_lock); | |
| if (unlikely(ret < 0)) | |
| return ret; | |
| *id = ret; | |
| return 0; | |
| } | |
| /** | |
| * release_idr - function to free the unique id. | |
| * @idr: struct idr * handle used for creating the id. | |
| * @id: int value representing the unique id. | |
| */ | |
| static void release_idr(struct idr *idr, int id) | |
| { | |
| mutex_lock(&cooling_cpufreq_lock); | |
| idr_remove(idr, id); | |
| mutex_unlock(&cooling_cpufreq_lock); | |
| } | |
| /* Below code defines functions to be used for cpufreq as cooling device */ | |
| /** | |
| * is_cpufreq_valid - function to check frequency transitioning capability. | |
| * @cpu: cpu for which check is needed. | |
| * | |
| * This function will check the current state of the system if | |
| * it is capable of changing the frequency for a given @cpu. | |
| * | |
| * Return: 0 if the system is not currently capable of changing | |
| * the frequency of given cpu. !0 in case the frequency is changeable. | |
| */ | |
| static int is_cpufreq_valid(int cpu) | |
| { | |
| struct cpufreq_policy policy; | |
| return !cpufreq_get_policy(&policy, cpu); | |
| } | |
| enum cpufreq_cooling_property { | |
| GET_LEVEL, | |
| GET_FREQ, | |
| GET_MAXL, | |
| }; | |
| /** | |
| * get_property - fetch a property of interest for a give cpu. | |
| * @cpu: cpu for which the property is required | |
| * @input: query parameter | |
| * @output: query return | |
| * @property: type of query (frequency, level, max level) | |
| * | |
| * This is the common function to | |
| * 1. get maximum cpu cooling states | |
| * 2. translate frequency to cooling state | |
| * 3. translate cooling state to frequency | |
| * Note that the code may be not in good shape | |
| * but it is written in this way in order to: | |
| * a) reduce duplicate code as most of the code can be shared. | |
| * b) make sure the logic is consistent when translating between | |
| * cooling states and frequencies. | |
| * | |
| * Return: 0 on success, -EINVAL when invalid parameters are passed. | |
| */ | |
| static int get_property(unsigned int cpu, unsigned long input, | |
| unsigned int *output, | |
| enum cpufreq_cooling_property property) | |
| { | |
| int i, j; | |
| unsigned long max_level = 0, level = 0; | |
| unsigned int freq = CPUFREQ_ENTRY_INVALID; | |
| int descend = -1; | |
| struct cpufreq_frequency_table *table = | |
| cpufreq_frequency_get_table(cpu); | |
| if (!output) | |
| return -EINVAL; | |
| if (!table) | |
| return -EINVAL; | |
| for (i = 0; table[i].frequency != CPUFREQ_TABLE_END; i++) { | |
| /* ignore invalid entries */ | |
| if (table[i].frequency == CPUFREQ_ENTRY_INVALID) | |
| continue; | |
| /* ignore duplicate entry */ | |
| if (freq == table[i].frequency) | |
| continue; | |
| /* get the frequency order */ | |
| if (freq != CPUFREQ_ENTRY_INVALID && descend == -1) | |
| descend = !!(freq > table[i].frequency); | |
| freq = table[i].frequency; | |
| max_level++; | |
| } | |
| /* No valid cpu frequency entry */ | |
| if (max_level == 0) | |
| return -EINVAL; | |
| /* max_level is an index, not a counter */ | |
| max_level--; | |
| /* get max level */ | |
| if (property == GET_MAXL) { | |
| *output = (unsigned int)max_level; | |
| return 0; | |
| } | |
| if (property == GET_FREQ) | |
| level = descend ? input : (max_level - input); | |
| for (i = 0, j = 0; table[i].frequency != CPUFREQ_TABLE_END; i++) { | |
| /* ignore invalid entry */ | |
| if (table[i].frequency == CPUFREQ_ENTRY_INVALID) | |
| continue; | |
| /* ignore duplicate entry */ | |
| if (freq == table[i].frequency) | |
| continue; | |
| /* now we have a valid frequency entry */ | |
| freq = table[i].frequency; | |
| if (property == GET_LEVEL && (unsigned int)input == freq) { | |
| /* get level by frequency */ | |
| *output = descend ? j : (max_level - j); | |
| return 0; | |
| } | |
| if (property == GET_FREQ && level == j) { | |
| /* get frequency by level */ | |
| *output = freq; | |
| return 0; | |
| } | |
| j++; | |
| } | |
| return -EINVAL; | |
| } | |
| /** | |
| * cpufreq_cooling_get_level - for a give cpu, return the cooling level. | |
| * @cpu: cpu for which the level is required | |
| * @freq: the frequency of interest | |
| * | |
| * This function will match the cooling level corresponding to the | |
| * requested @freq and return it. | |
| * | |
| * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID | |
| * otherwise. | |
| */ | |
| unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq) | |
| { | |
| unsigned int val; | |
| if (get_property(cpu, (unsigned long)freq, &val, GET_LEVEL)) | |
| return THERMAL_CSTATE_INVALID; | |
| return (unsigned long)val; | |
| } | |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level); | |
| /** | |
| * get_cpu_frequency - get the absolute value of frequency from level. | |
| * @cpu: cpu for which frequency is fetched. | |
| * @level: cooling level | |
| * | |
| * This function matches cooling level with frequency. Based on a cooling level | |
| * of frequency, equals cooling state of cpu cooling device, it will return | |
| * the corresponding frequency. | |
| * e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc | |
| * | |
| * Return: 0 on error, the corresponding frequency otherwise. | |
| */ | |
| static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level) | |
| { | |
| int ret = 0; | |
| unsigned int freq; | |
| ret = get_property(cpu, level, &freq, GET_FREQ); | |
| if (ret) | |
| return 0; | |
| return freq; | |
| } | |
| /** | |
| * cpufreq_apply_cooling - function to apply frequency clipping. | |
| * @cpufreq_device: cpufreq_cooling_device pointer containing frequency | |
| * clipping data. | |
| * @cooling_state: value of the cooling state. | |
| * | |
| * Function used to make sure the cpufreq layer is aware of current thermal | |
| * limits. The limits are applied by updating the cpufreq policy. | |
| * | |
| * Return: 0 on success, an error code otherwise (-EINVAL in case wrong | |
| * cooling state). | |
| */ | |
| static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device, | |
| unsigned long cooling_state) | |
| { | |
| unsigned int cpuid, clip_freq; | |
| struct cpumask *mask = &cpufreq_device->allowed_cpus; | |
| unsigned int cpu = cpumask_any(mask); | |
| /* Check if the old cooling action is same as new cooling action */ | |
| if (cpufreq_device->cpufreq_state == cooling_state) | |
| return 0; | |
| clip_freq = get_cpu_frequency(cpu, cooling_state); | |
| if (!clip_freq) | |
| return -EINVAL; | |
| cpufreq_device->cpufreq_state = cooling_state; | |
| cpufreq_device->cpufreq_val = clip_freq; | |
| notify_device = cpufreq_device; | |
| for_each_cpu(cpuid, mask) { | |
| if (is_cpufreq_valid(cpuid)) | |
| cpufreq_update_policy(cpuid); | |
| } | |
| notify_device = NOTIFY_INVALID; | |
| return 0; | |
| } | |
| /** | |
| * cpufreq_thermal_notifier - notifier callback for cpufreq policy change. | |
| * @nb: struct notifier_block * with callback info. | |
| * @event: value showing cpufreq event for which this function invoked. | |
| * @data: callback-specific data | |
| * | |
| * Callback to highjack the notification on cpufreq policy transition. | |
| * Every time there is a change in policy, we will intercept and | |
| * update the cpufreq policy with thermal constraints. | |
| * | |
| * Return: 0 (success) | |
| */ | |
| static int cpufreq_thermal_notifier(struct notifier_block *nb, | |
| unsigned long event, void *data) | |
| { | |
| struct cpufreq_policy *policy = data; | |
| unsigned long max_freq = 0; | |
| if (event != CPUFREQ_ADJUST || notify_device == NOTIFY_INVALID) | |
| return 0; | |
| if (cpumask_test_cpu(policy->cpu, ¬ify_device->allowed_cpus)) | |
| max_freq = notify_device->cpufreq_val; | |
| else | |
| return 0; | |
| /* Never exceed user_policy.max */ | |
| if (max_freq > policy->user_policy.max) | |
| max_freq = policy->user_policy.max; | |
| if (policy->max != max_freq) | |
| cpufreq_verify_within_limits(policy, 0, max_freq); | |
| return 0; | |
| } | |
| /* cpufreq cooling device callback functions are defined below */ | |
| /** | |
| * cpufreq_get_max_state - callback function to get the max cooling state. | |
| * @cdev: thermal cooling device pointer. | |
| * @state: fill this variable with the max cooling state. | |
| * | |
| * Callback for the thermal cooling device to return the cpufreq | |
| * max cooling state. | |
| * | |
| * Return: 0 on success, an error code otherwise. | |
| */ | |
| static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, | |
| unsigned long *state) | |
| { | |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; | |
| struct cpumask *mask = &cpufreq_device->allowed_cpus; | |
| unsigned int cpu; | |
| unsigned int count = 0; | |
| int ret; | |
| cpu = cpumask_any(mask); | |
| ret = get_property(cpu, 0, &count, GET_MAXL); | |
| if (count > 0) | |
| *state = count; | |
| return ret; | |
| } | |
| /** | |
| * cpufreq_get_cur_state - callback function to get the current cooling state. | |
| * @cdev: thermal cooling device pointer. | |
| * @state: fill this variable with the current cooling state. | |
| * | |
| * Callback for the thermal cooling device to return the cpufreq | |
| * current cooling state. | |
| * | |
| * Return: 0 on success, an error code otherwise. | |
| */ | |
| static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, | |
| unsigned long *state) | |
| { | |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; | |
| *state = cpufreq_device->cpufreq_state; | |
| return 0; | |
| } | |
| /** | |
| * cpufreq_set_cur_state - callback function to set the current cooling state. | |
| * @cdev: thermal cooling device pointer. | |
| * @state: set this variable to the current cooling state. | |
| * | |
| * Callback for the thermal cooling device to change the cpufreq | |
| * current cooling state. | |
| * | |
| * Return: 0 on success, an error code otherwise. | |
| */ | |
| static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, | |
| unsigned long state) | |
| { | |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; | |
| return cpufreq_apply_cooling(cpufreq_device, state); | |
| } | |
| /* Bind cpufreq callbacks to thermal cooling device ops */ | |
| static struct thermal_cooling_device_ops const cpufreq_cooling_ops = { | |
| .get_max_state = cpufreq_get_max_state, | |
| .get_cur_state = cpufreq_get_cur_state, | |
| .set_cur_state = cpufreq_set_cur_state, | |
| }; | |
| /* Notifier for cpufreq policy change */ | |
| static struct notifier_block thermal_cpufreq_notifier_block = { | |
| .notifier_call = cpufreq_thermal_notifier, | |
| }; | |
| /** | |
| * __cpufreq_cooling_register - helper function to create cpufreq cooling device | |
| * @np: a valid struct device_node to the cooling device device tree node | |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen. | |
| * | |
| * This interface function registers the cpufreq cooling device with the name | |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq | |
| * cooling devices. It also gives the opportunity to link the cooling device | |
| * with a device tree node, in order to bind it via the thermal DT code. | |
| * | |
| * Return: a valid struct thermal_cooling_device pointer on success, | |
| * on failure, it returns a corresponding ERR_PTR(). | |
| */ | |
| static struct thermal_cooling_device * | |
| __cpufreq_cooling_register(struct device_node *np, | |
| const struct cpumask *clip_cpus) | |
| { | |
| struct thermal_cooling_device *cool_dev; | |
| struct cpufreq_cooling_device *cpufreq_dev = NULL; | |
| unsigned int min = 0, max = 0; | |
| char dev_name[THERMAL_NAME_LENGTH]; | |
| int ret = 0, i; | |
| struct cpufreq_policy policy; | |
| /* Verify that all the clip cpus have same freq_min, freq_max limit */ | |
| for_each_cpu(i, clip_cpus) { | |
| /* continue if cpufreq policy not found and not return error */ | |
| if (!cpufreq_get_policy(&policy, i)) | |
| continue; | |
| if (min == 0 && max == 0) { | |
| min = policy.cpuinfo.min_freq; | |
| max = policy.cpuinfo.max_freq; | |
| } else { | |
| if (min != policy.cpuinfo.min_freq || | |
| max != policy.cpuinfo.max_freq) | |
| return ERR_PTR(-EINVAL); | |
| } | |
| } | |
| cpufreq_dev = kzalloc(sizeof(struct cpufreq_cooling_device), | |
| GFP_KERNEL); | |
| if (!cpufreq_dev) | |
| return ERR_PTR(-ENOMEM); | |
| cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus); | |
| ret = get_idr(&cpufreq_idr, &cpufreq_dev->id); | |
| if (ret) { | |
| kfree(cpufreq_dev); | |
| return ERR_PTR(-EINVAL); | |
| } | |
| snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d", | |
| cpufreq_dev->id); | |
| cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev, | |
| &cpufreq_cooling_ops); | |
| if (IS_ERR(cool_dev)) { | |
| release_idr(&cpufreq_idr, cpufreq_dev->id); | |
| kfree(cpufreq_dev); | |
| return cool_dev; | |
| } | |
| cpufreq_dev->cool_dev = cool_dev; | |
| cpufreq_dev->cpufreq_state = 0; | |
| mutex_lock(&cooling_cpufreq_lock); | |
| /* Register the notifier for first cpufreq cooling device */ | |
| if (cpufreq_dev_count == 0) | |
| cpufreq_register_notifier(&thermal_cpufreq_notifier_block, | |
| CPUFREQ_POLICY_NOTIFIER); | |
| cpufreq_dev_count++; | |
| mutex_unlock(&cooling_cpufreq_lock); | |
| return cool_dev; | |
| } | |
| /** | |
| * cpufreq_cooling_register - function to create cpufreq cooling device. | |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen. | |
| * | |
| * This interface function registers the cpufreq cooling device with the name | |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq | |
| * cooling devices. | |
| * | |
| * Return: a valid struct thermal_cooling_device pointer on success, | |
| * on failure, it returns a corresponding ERR_PTR(). | |
| */ | |
| struct thermal_cooling_device * | |
| cpufreq_cooling_register(const struct cpumask *clip_cpus) | |
| { | |
| return __cpufreq_cooling_register(NULL, clip_cpus); | |
| } | |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_register); | |
| /** | |
| * of_cpufreq_cooling_register - function to create cpufreq cooling device. | |
| * @np: a valid struct device_node to the cooling device device tree node | |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen. | |
| * | |
| * This interface function registers the cpufreq cooling device with the name | |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq | |
| * cooling devices. Using this API, the cpufreq cooling device will be | |
| * linked to the device tree node provided. | |
| * | |
| * Return: a valid struct thermal_cooling_device pointer on success, | |
| * on failure, it returns a corresponding ERR_PTR(). | |
| */ | |
| struct thermal_cooling_device * | |
| of_cpufreq_cooling_register(struct device_node *np, | |
| const struct cpumask *clip_cpus) | |
| { | |
| if (!np) | |
| return ERR_PTR(-EINVAL); | |
| return __cpufreq_cooling_register(np, clip_cpus); | |
| } | |
| EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); | |
| /** | |
| * cpufreq_cooling_unregister - function to remove cpufreq cooling device. | |
| * @cdev: thermal cooling device pointer. | |
| * | |
| * This interface function unregisters the "thermal-cpufreq-%x" cooling device. | |
| */ | |
| void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) | |
| { | |
| struct cpufreq_cooling_device *cpufreq_dev; | |
| if (!cdev) | |
| return; | |
| cpufreq_dev = cdev->devdata; | |
| mutex_lock(&cooling_cpufreq_lock); | |
| cpufreq_dev_count--; | |
| /* Unregister the notifier for the last cpufreq cooling device */ | |
| if (cpufreq_dev_count == 0) | |
| cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block, | |
| CPUFREQ_POLICY_NOTIFIER); | |
| mutex_unlock(&cooling_cpufreq_lock); | |
| thermal_cooling_device_unregister(cpufreq_dev->cool_dev); | |
| release_idr(&cpufreq_idr, cpufreq_dev->id); | |
| kfree(cpufreq_dev); | |
| } | |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister); |