|  | /* | 
|  | *  thermal.h  ($Revision: 0 $) | 
|  | * | 
|  | *  Copyright (C) 2008  Intel Corp | 
|  | *  Copyright (C) 2008  Zhang Rui <rui.zhang@intel.com> | 
|  | *  Copyright (C) 2008  Sujith Thomas <sujith.thomas@intel.com> | 
|  | * | 
|  | * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | 
|  | *  This program is free software; you can redistribute it and/or modify | 
|  | *  it under the terms of the GNU General Public License as published by | 
|  | *  the Free Software Foundation; version 2 of the License. | 
|  | * | 
|  | *  This program is distributed in the hope that it will be useful, but | 
|  | *  WITHOUT ANY WARRANTY; without even the implied warranty of | 
|  | *  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU | 
|  | *  General Public License for more details. | 
|  | * | 
|  | *  You should have received a copy of the GNU General Public License along | 
|  | *  with this program; if not, write to the Free Software Foundation, Inc., | 
|  | *  59 Temple Place, Suite 330, Boston, MA 02111-1307 USA. | 
|  | * | 
|  | * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | 
|  | */ | 
|  |  | 
|  | #ifndef __THERMAL_H__ | 
|  | #define __THERMAL_H__ | 
|  |  | 
|  | #include <linux/of.h> | 
|  | #include <linux/idr.h> | 
|  | #include <linux/device.h> | 
|  | #include <linux/workqueue.h> | 
|  |  | 
|  | #define THERMAL_TRIPS_NONE	-1 | 
|  | #define THERMAL_MAX_TRIPS	12 | 
|  | #define THERMAL_NAME_LENGTH	20 | 
|  |  | 
|  | /* invalid cooling state */ | 
|  | #define THERMAL_CSTATE_INVALID -1UL | 
|  |  | 
|  | /* No upper/lower limit requirement */ | 
|  | #define THERMAL_NO_LIMIT	THERMAL_CSTATE_INVALID | 
|  |  | 
|  | /* Unit conversion macros */ | 
|  | #define KELVIN_TO_CELSIUS(t)	(long)(((long)t-2732 >= 0) ?	\ | 
|  | ((long)t-2732+5)/10 : ((long)t-2732-5)/10) | 
|  | #define CELSIUS_TO_KELVIN(t)	((t)*10+2732) | 
|  |  | 
|  | /* Adding event notification support elements */ | 
|  | #define THERMAL_GENL_FAMILY_NAME                "thermal_event" | 
|  | #define THERMAL_GENL_VERSION                    0x01 | 
|  | #define THERMAL_GENL_MCAST_GROUP_NAME           "thermal_mc_grp" | 
|  |  | 
|  | /* Default Thermal Governor */ | 
|  | #if defined(CONFIG_THERMAL_DEFAULT_GOV_STEP_WISE) | 
|  | #define DEFAULT_THERMAL_GOVERNOR       "step_wise" | 
|  | #elif defined(CONFIG_THERMAL_DEFAULT_GOV_FAIR_SHARE) | 
|  | #define DEFAULT_THERMAL_GOVERNOR       "fair_share" | 
|  | #elif defined(CONFIG_THERMAL_DEFAULT_GOV_USER_SPACE) | 
|  | #define DEFAULT_THERMAL_GOVERNOR       "user_space" | 
|  | #endif | 
|  |  | 
|  | struct thermal_zone_device; | 
|  | struct thermal_cooling_device; | 
|  |  | 
|  | enum thermal_device_mode { | 
|  | THERMAL_DEVICE_DISABLED = 0, | 
|  | THERMAL_DEVICE_ENABLED, | 
|  | }; | 
|  |  | 
|  | enum thermal_trip_type { | 
|  | THERMAL_TRIP_ACTIVE = 0, | 
|  | THERMAL_TRIP_PASSIVE, | 
|  | THERMAL_TRIP_HOT, | 
|  | THERMAL_TRIP_CRITICAL, | 
|  | }; | 
|  |  | 
|  | enum thermal_trend { | 
|  | THERMAL_TREND_STABLE, /* temperature is stable */ | 
|  | THERMAL_TREND_RAISING, /* temperature is raising */ | 
|  | THERMAL_TREND_DROPPING, /* temperature is dropping */ | 
|  | THERMAL_TREND_RAISE_FULL, /* apply highest cooling action */ | 
|  | THERMAL_TREND_DROP_FULL, /* apply lowest cooling action */ | 
|  | }; | 
|  |  | 
|  | /* Events supported by Thermal Netlink */ | 
|  | enum events { | 
|  | THERMAL_AUX0, | 
|  | THERMAL_AUX1, | 
|  | THERMAL_CRITICAL, | 
|  | THERMAL_DEV_FAULT, | 
|  | }; | 
|  |  | 
|  | /* attributes of thermal_genl_family */ | 
|  | enum { | 
|  | THERMAL_GENL_ATTR_UNSPEC, | 
|  | THERMAL_GENL_ATTR_EVENT, | 
|  | __THERMAL_GENL_ATTR_MAX, | 
|  | }; | 
|  | #define THERMAL_GENL_ATTR_MAX (__THERMAL_GENL_ATTR_MAX - 1) | 
|  |  | 
|  | /* commands supported by the thermal_genl_family */ | 
|  | enum { | 
|  | THERMAL_GENL_CMD_UNSPEC, | 
|  | THERMAL_GENL_CMD_EVENT, | 
|  | __THERMAL_GENL_CMD_MAX, | 
|  | }; | 
|  | #define THERMAL_GENL_CMD_MAX (__THERMAL_GENL_CMD_MAX - 1) | 
|  |  | 
|  | struct thermal_zone_device_ops { | 
|  | int (*bind) (struct thermal_zone_device *, | 
|  | struct thermal_cooling_device *); | 
|  | int (*unbind) (struct thermal_zone_device *, | 
|  | struct thermal_cooling_device *); | 
|  | int (*get_temp) (struct thermal_zone_device *, unsigned long *); | 
|  | int (*get_mode) (struct thermal_zone_device *, | 
|  | enum thermal_device_mode *); | 
|  | int (*set_mode) (struct thermal_zone_device *, | 
|  | enum thermal_device_mode); | 
|  | int (*get_trip_type) (struct thermal_zone_device *, int, | 
|  | enum thermal_trip_type *); | 
|  | int (*get_trip_temp) (struct thermal_zone_device *, int, | 
|  | unsigned long *); | 
|  | int (*set_trip_temp) (struct thermal_zone_device *, int, | 
|  | unsigned long); | 
|  | int (*get_trip_hyst) (struct thermal_zone_device *, int, | 
|  | unsigned long *); | 
|  | int (*set_trip_hyst) (struct thermal_zone_device *, int, | 
|  | unsigned long); | 
|  | int (*get_crit_temp) (struct thermal_zone_device *, unsigned long *); | 
|  | int (*set_emul_temp) (struct thermal_zone_device *, unsigned long); | 
|  | int (*get_trend) (struct thermal_zone_device *, int, | 
|  | enum thermal_trend *); | 
|  | int (*notify) (struct thermal_zone_device *, int, | 
|  | enum thermal_trip_type); | 
|  | }; | 
|  |  | 
|  | struct thermal_cooling_device_ops { | 
|  | int (*get_max_state) (struct thermal_cooling_device *, unsigned long *); | 
|  | int (*get_cur_state) (struct thermal_cooling_device *, unsigned long *); | 
|  | int (*set_cur_state) (struct thermal_cooling_device *, unsigned long); | 
|  | }; | 
|  |  | 
|  | struct thermal_cooling_device { | 
|  | int id; | 
|  | char type[THERMAL_NAME_LENGTH]; | 
|  | struct device device; | 
|  | struct device_node *np; | 
|  | void *devdata; | 
|  | const struct thermal_cooling_device_ops *ops; | 
|  | bool updated; /* true if the cooling device does not need update */ | 
|  | struct mutex lock; /* protect thermal_instances list */ | 
|  | struct list_head thermal_instances; | 
|  | struct list_head node; | 
|  | }; | 
|  |  | 
|  | struct thermal_attr { | 
|  | struct device_attribute attr; | 
|  | char name[THERMAL_NAME_LENGTH]; | 
|  | }; | 
|  |  | 
|  | struct thermal_zone_device { | 
|  | int id; | 
|  | char type[THERMAL_NAME_LENGTH]; | 
|  | struct device device; | 
|  | struct thermal_attr *trip_temp_attrs; | 
|  | struct thermal_attr *trip_type_attrs; | 
|  | struct thermal_attr *trip_hyst_attrs; | 
|  | void *devdata; | 
|  | int trips; | 
|  | int passive_delay; | 
|  | int polling_delay; | 
|  | int temperature; | 
|  | int last_temperature; | 
|  | int emul_temperature; | 
|  | int passive; | 
|  | unsigned int forced_passive; | 
|  | struct thermal_zone_device_ops *ops; | 
|  | const struct thermal_zone_params *tzp; | 
|  | struct thermal_governor *governor; | 
|  | struct list_head thermal_instances; | 
|  | struct idr idr; | 
|  | struct mutex lock; /* protect thermal_instances list */ | 
|  | struct list_head node; | 
|  | struct delayed_work poll_queue; | 
|  | }; | 
|  |  | 
|  | /* Structure that holds thermal governor information */ | 
|  | struct thermal_governor { | 
|  | char name[THERMAL_NAME_LENGTH]; | 
|  | int (*throttle)(struct thermal_zone_device *tz, int trip); | 
|  | struct list_head	governor_list; | 
|  | }; | 
|  |  | 
|  | /* Structure that holds binding parameters for a zone */ | 
|  | struct thermal_bind_params { | 
|  | struct thermal_cooling_device *cdev; | 
|  |  | 
|  | /* | 
|  | * This is a measure of 'how effectively these devices can | 
|  | * cool 'this' thermal zone. The shall be determined by platform | 
|  | * characterization. This is on a 'percentage' scale. | 
|  | * See Documentation/thermal/sysfs-api.txt for more information. | 
|  | */ | 
|  | int weight; | 
|  |  | 
|  | /* | 
|  | * This is a bit mask that gives the binding relation between this | 
|  | * thermal zone and cdev, for a particular trip point. | 
|  | * See Documentation/thermal/sysfs-api.txt for more information. | 
|  | */ | 
|  | int trip_mask; | 
|  |  | 
|  | /* | 
|  | * This is an array of cooling state limits. Must have exactly | 
|  | * 2 * thermal_zone.number_of_trip_points. It is an array consisting | 
|  | * of tuples <lower-state upper-state> of state limits. Each trip | 
|  | * will be associated with one state limit tuple when binding. | 
|  | * A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS> | 
|  | * on all trips. | 
|  | */ | 
|  | unsigned long *binding_limits; | 
|  | int (*match) (struct thermal_zone_device *tz, | 
|  | struct thermal_cooling_device *cdev); | 
|  | }; | 
|  |  | 
|  | /* Structure to define Thermal Zone parameters */ | 
|  | struct thermal_zone_params { | 
|  | char governor_name[THERMAL_NAME_LENGTH]; | 
|  |  | 
|  | /* | 
|  | * a boolean to indicate if the thermal to hwmon sysfs interface | 
|  | * is required. when no_hwmon == false, a hwmon sysfs interface | 
|  | * will be created. when no_hwmon == true, nothing will be done | 
|  | */ | 
|  | bool no_hwmon; | 
|  |  | 
|  | int num_tbps;	/* Number of tbp entries */ | 
|  | struct thermal_bind_params *tbp; | 
|  | }; | 
|  |  | 
|  | struct thermal_genl_event { | 
|  | u32 orig; | 
|  | enum events event; | 
|  | }; | 
|  |  | 
|  | /* Function declarations */ | 
|  | #ifdef CONFIG_THERMAL_OF | 
|  | struct thermal_zone_device * | 
|  | thermal_zone_of_sensor_register(struct device *dev, int id, | 
|  | void *data, int (*get_temp)(void *, long *), | 
|  | int (*get_trend)(void *, long *)); | 
|  | void thermal_zone_of_sensor_unregister(struct device *dev, | 
|  | struct thermal_zone_device *tz); | 
|  | #else | 
|  | static inline struct thermal_zone_device * | 
|  | thermal_zone_of_sensor_register(struct device *dev, int id, | 
|  | void *data, int (*get_temp)(void *, long *), | 
|  | int (*get_trend)(void *, long *)) | 
|  | { | 
|  | return NULL; | 
|  | } | 
|  |  | 
|  | static inline | 
|  | void thermal_zone_of_sensor_unregister(struct device *dev, | 
|  | struct thermal_zone_device *tz) | 
|  | { | 
|  | } | 
|  |  | 
|  | #endif | 
|  | struct thermal_zone_device *thermal_zone_device_register(const char *, int, int, | 
|  | void *, struct thermal_zone_device_ops *, | 
|  | const struct thermal_zone_params *, int, int); | 
|  | void thermal_zone_device_unregister(struct thermal_zone_device *); | 
|  |  | 
|  | int thermal_zone_bind_cooling_device(struct thermal_zone_device *, int, | 
|  | struct thermal_cooling_device *, | 
|  | unsigned long, unsigned long); | 
|  | int thermal_zone_unbind_cooling_device(struct thermal_zone_device *, int, | 
|  | struct thermal_cooling_device *); | 
|  | void thermal_zone_device_update(struct thermal_zone_device *); | 
|  |  | 
|  | struct thermal_cooling_device *thermal_cooling_device_register(char *, void *, | 
|  | const struct thermal_cooling_device_ops *); | 
|  | struct thermal_cooling_device * | 
|  | thermal_of_cooling_device_register(struct device_node *np, char *, void *, | 
|  | const struct thermal_cooling_device_ops *); | 
|  | void thermal_cooling_device_unregister(struct thermal_cooling_device *); | 
|  | struct thermal_zone_device *thermal_zone_get_zone_by_name(const char *name); | 
|  | int thermal_zone_get_temp(struct thermal_zone_device *tz, unsigned long *temp); | 
|  |  | 
|  | int get_tz_trend(struct thermal_zone_device *, int); | 
|  | struct thermal_instance *get_thermal_instance(struct thermal_zone_device *, | 
|  | struct thermal_cooling_device *, int); | 
|  | void thermal_cdev_update(struct thermal_cooling_device *); | 
|  | void thermal_notify_framework(struct thermal_zone_device *, int); | 
|  |  | 
|  | #ifdef CONFIG_NET | 
|  | extern int thermal_generate_netlink_event(struct thermal_zone_device *tz, | 
|  | enum events event); | 
|  | #else | 
|  | static inline int thermal_generate_netlink_event(struct thermal_zone_device *tz, | 
|  | enum events event) | 
|  | { | 
|  | return 0; | 
|  | } | 
|  | #endif | 
|  |  | 
|  | #endif /* __THERMAL_H__ */ |