| * Marvell Orion Watchdog Time |
| |
| Required Properties: |
| |
| - Compatibility : "marvell,orion-wdt" |
| "marvell,armada-370-wdt" |
| "marvell,armada-xp-wdt" |
| "marvell,armada-375-wdt" |
| "marvell,armada-380-wdt" |
| |
| - reg : Should contain two entries: first one with the |
| timer control address, second one with the |
| rstout enable address. |
| |
| For "marvell,armada-375-wdt" and "marvell,armada-380-wdt": |
| |
| - reg : A third entry is mandatory and should contain the |
| shared mask/unmask RSTOUT address. |
| |
| Optional properties: |
| |
| - interrupts : Contains the IRQ for watchdog expiration |
| - timeout-sec : Contains the watchdog timeout in seconds |
| |
| Example: |
| |
| wdt@20300 { |
| compatible = "marvell,orion-wdt"; |
| reg = <0x20300 0x28>, <0x20108 0x4>; |
| interrupts = <3>; |
| timeout-sec = <10>; |
| status = "okay"; |
| }; |