blob: e746b631793af9e2c01d7a33d186f263c9efae97 [file] [log] [blame]
Amlogic Meson SoC Reset Controller
=======================================
Please also refer to reset.txt in this directory for common reset
controller binding usage.
Required properties:
- compatible: Should be "amlogic,meson8b-reset" or "amlogic,meson-gxbb-reset"
- reg: should contain the register address base
- #reset-cells: 1, see below
example:
reset: reset-controller {
compatible = "amlogic,meson-gxbb-reset";
reg = <0x0 0x04404 0x0 0x20>;
#reset-cells = <1>;
};