| .TH TMON 8 | |
| # SPDX-License-Identifier: GPL-2.0 | |
| .SH NAME | |
| \fBtmon\fP - A monitoring and testing tool for Linux kernel thermal subsystem | |
| .SH SYNOPSIS | |
| .ft B | |
| .B tmon | |
| .RB [ Options ] | |
| .br | |
| .SH DESCRIPTION | |
| \fBtmon \fP can be used to visualize thermal relationship and | |
| real-time thermal data; tune | |
| and test cooling devices and sensors; collect thermal data for offline | |
| analysis and plot. \fBtmon\fP must be run as root in order to control device | |
| states via sysfs. | |
| .PP | |
| \fBFunctions\fP | |
| .PP | |
| .nf | |
| 1. Thermal relationships: | |
| - show thermal zone information | |
| - show cooling device information | |
| - show trip point binding within each thermal zone | |
| - show trip point and cooling device instance bindings | |
| .PP | |
| 2. Real time data display | |
| - show temperature of all thermal zones w.r.t. its trip points and types | |
| - show states of all cooling devices | |
| .PP | |
| 3. Thermal relationship learning and device tuning | |
| - with a built-in Proportional Integral Derivative (\fBPID\fP) | |
| controller, user can pair a cooling device to a thermal sensor for | |
| testing the effectiveness and learn about the thermal distance between the two | |
| - allow manual control of cooling device states and target temperature | |
| .PP | |
| 4. Data logging in /var/tmp/tmon.log | |
| - contains thermal configuration data, i.e. cooling device, thermal | |
| zones, and trip points. Can be used for data collection in remote | |
| debugging. | |
| - log real-time thermal data into space separated format that can be | |
| directly consumed by plotting tools such as Rscript. | |
| .SS Options | |
| .PP | |
| The \fB-c --control\fP option sets a cooling device type to control temperature | |
| of a thermal zone | |
| .PP | |
| The \fB-d --daemon\fP option runs \fBtmon \fP as daemon without user interface | |
| .PP | |
| The \fB-g --debug\fP option allow debug messages to be stored in syslog | |
| .PP | |
| The \fB-h --help\fP option shows help message | |
| .PP | |
| The \fB-l --log\fP option write data to /var/tmp/tmon.log | |
| .PP | |
| The \fB-t --time-interval\fP option sets the polling interval in seconds | |
| .PP | |
| The \fB-T --target-temp\fP option sets the initial target temperature | |
| .PP | |
| The \fB-v --version\fP option shows the version of \fBtmon \fP | |
| .PP | |
| The \fB-z --zone\fP option sets the target therma zone instance to be controlled | |
| .PP | |
| .SH FIELD DESCRIPTIONS | |
| .nf | |
| .PP | |
| \fBP \fP passive cooling trip point type | |
| \fBA \fP active cooling trip point type (fan) | |
| \fBC \fP critical trip point type | |
| \fBA \fP hot trip point type | |
| \fBkp \fP proportional gain of \fBPID\fP controller | |
| \fBki \fP integral gain of \fBPID\fP controller | |
| \fBkd \fP derivative gain of \fBPID\fP controller | |
| .SH REQUIREMENT | |
| Build depends on ncurses | |
| .PP | |
| Runtime depends on window size large enough to show the number of | |
| devices found on the system. | |
| .PP | |
| .SH INTERACTIVE COMMANDS | |
| .pp | |
| .nf | |
| \fBCtrl-C, q/Q\fP stops \fBtmon\fP | |
| \fBTAB\fP shows tuning pop up panel, choose a letter to modify | |
| .SH EXAMPLES | |
| Without any parameters, tmon is in monitoring only mode and refresh | |
| screen every 1 second. | |
| .PP | |
| 1. For monitoring only: | |
| .nf | |
| $ sudo ./tmon | |
| 2. Use Processor cooling device to control thermal zone 0 at default 65C. | |
| $ sudo ./tmon -c Processor -z 0 | |
| 3. Use intel_powerclamp(idle injection) cooling device to control thermal zone 1 | |
| $ sudo ./tmon -c intel_powerclamp -z 1 | |
| 4. Turn on debug and collect data log at /var/tmp/tmon.log | |
| $ sudo ./tmon -g -l | |
| For example, the log below shows PID controller was adjusting current states | |
| for all cooling devices with "Processor" type such that thermal zone 0 | |
| can stay below 65 dC. | |
| #---------- THERMAL DATA LOG STARTED ----------- | |
| Samples TargetTemp acpitz0 acpitz1 Fan0 Fan1 Fan2 Fan3 Fan4 Fan5 | |
| Fan6 Fan7 Fan8 Fan9 Processor10 Processor11 Processor12 Processor13 | |
| LCD14 intel_powerclamp15 1 65.0 65 65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 2 | |
| 65.0 66 65 0 0 0 0 0 0 0 0 0 0 4 4 4 4 6 0 3 65.0 60 54 0 0 0 0 0 0 0 0 | |
| 0 0 4 4 4 4 6 0 4 65.0 53 53 0 0 0 0 0 0 0 0 0 0 4 4 4 4 6 0 | |
| 5 65.0 52 52 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 | |
| 6 65.0 53 65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 | |
| 7 65.0 68 70 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 | |
| 8 65.0 68 68 0 0 0 0 0 0 0 0 0 0 5 5 5 5 6 0 | |
| 9 65.0 68 68 0 0 0 0 0 0 0 0 0 0 6 6 6 6 6 0 | |
| 10 65.0 67 67 0 0 0 0 0 0 0 0 0 0 7 7 7 7 6 0 | |
| 11 65.0 67 67 0 0 0 0 0 0 0 0 0 0 8 8 8 8 6 0 | |
| 12 65.0 67 67 0 0 0 0 0 0 0 0 0 0 8 8 8 8 6 0 | |
| 13 65.0 67 67 0 0 0 0 0 0 0 0 0 0 9 9 9 9 6 0 | |
| 14 65.0 66 66 0 0 0 0 0 0 0 0 0 0 10 10 10 10 6 0 | |
| 15 65.0 66 67 0 0 0 0 0 0 0 0 0 0 10 10 10 10 6 0 | |
| 16 65.0 66 66 0 0 0 0 0 0 0 0 0 0 11 11 11 11 6 0 | |
| 17 65.0 66 66 0 0 0 0 0 0 0 0 0 0 11 11 11 11 6 0 | |
| 18 65.0 64 61 0 0 0 0 0 0 0 0 0 0 11 11 11 11 6 0 | |
| 19 65.0 60 59 0 0 0 0 0 0 0 0 0 0 12 12 12 12 6 0 | |
| Data can be read directly into an array by an example R-script below: | |
| #!/usr/bin/Rscript | |
| tdata <- read.table("/var/tmp/tmon.log", header=T, comment.char="#") | |
| attach(tdata) | |
| jpeg("tmon.jpg") | |
| X11() | |
| g_range <- range(0, intel_powerclamp15, TargetTemp, acpitz0) | |
| plot( Samples, intel_powerclamp15, col="blue", ylim=g_range, axes=FALSE, ann=FALSE) | |
| par(new=TRUE) | |
| lines(TargetTemp, type="o", pch=22, lty=2, col="red") | |
| dev.off() |