| * Universal Flash Storage (UFS) Host Controller |
| |
| UFSHC nodes are defined to describe on-chip UFS host controllers. |
| Each UFS controller instance should have its own node. |
| |
| Required properties: |
| - compatible : must contain "jedec,ufs-1.1" or "jedec,ufs-2.0", may |
| also list one or more of the following: |
| "qcom,msm8994-ufshc" |
| "qcom,msm8996-ufshc" |
| "qcom,ufshc" |
| - interrupts : <interrupt mapping for UFS host controller IRQ> |
| - reg : <registers mapping> |
| |
| Optional properties: |
| - phys : phandle to UFS PHY node |
| - phy-names : the string "ufsphy" when is found in a node, along |
| with "phys" attribute, provides phandle to UFS PHY node |
| - vdd-hba-supply : phandle to UFS host controller supply regulator node |
| - vcc-supply : phandle to VCC supply regulator node |
| - vccq-supply : phandle to VCCQ supply regulator node |
| - vccq2-supply : phandle to VCCQ2 supply regulator node |
| - vcc-supply-1p8 : For embedded UFS devices, valid VCC range is 1.7-1.95V |
| or 2.7-3.6V. This boolean property when set, specifies |
| to use low voltage range of 1.7-1.95V. Note for external |
| UFS cards this property is invalid and valid VCC range is |
| always 2.7-3.6V. |
| - vcc-max-microamp : specifies max. load that can be drawn from vcc supply |
| - vccq-max-microamp : specifies max. load that can be drawn from vccq supply |
| - vccq2-max-microamp : specifies max. load that can be drawn from vccq2 supply |
| - <name>-fixed-regulator : boolean property specifying that <name>-supply is a fixed regulator |
| |
| - clocks : List of phandle and clock specifier pairs |
| - clock-names : List of clock input name strings sorted in the same |
| order as the clocks property. |
| - freq-table-hz : Array of <min max> operating frequencies stored in the same |
| order as the clocks property. If this property is not |
| defined or a value in the array is "0" then it is assumed |
| that the frequency is set by the parent clock or a |
| fixed rate clock source. |
| -lanes-per-direction : number of lanes available per direction - either 1 or 2. |
| Note that it is assume same number of lanes is used both |
| directions at once. If not specified, default is 2 lanes per direction. |
| |
| Note: If above properties are not defined it can be assumed that the supply |
| regulators or clocks are always on. |
| |
| Example: |
| ufshc@0xfc598000 { |
| compatible = "jedec,ufs-1.1"; |
| reg = <0xfc598000 0x800>; |
| interrupts = <0 28 0>; |
| |
| vdd-hba-supply = <&xxx_reg0>; |
| vdd-hba-fixed-regulator; |
| vcc-supply = <&xxx_reg1>; |
| vcc-supply-1p8; |
| vccq-supply = <&xxx_reg2>; |
| vccq2-supply = <&xxx_reg3>; |
| vcc-max-microamp = 500000; |
| vccq-max-microamp = 200000; |
| vccq2-max-microamp = 200000; |
| |
| clocks = <&core 0>, <&ref 0>, <&iface 0>; |
| clock-names = "core_clk", "ref_clk", "iface_clk"; |
| freq-table-hz = <100000000 200000000>, <0 0>, <0 0>; |
| phys = <&ufsphy1>; |
| phy-names = "ufsphy"; |
| }; |