| * Amlogic GXBB AO Clock and Reset Unit |
| |
| The Amlogic GXBB AO clock controller generates and supplies clock to various |
| controllers within the Always-On part of the SoC. |
| |
| Required Properties: |
| |
| - compatible: value should be different for each SoC family as : |
| - GXBB (S905) : "amlogic,meson-gxbb-aoclkc" |
| - GXL (S905X, S905D) : "amlogic,meson-gxl-aoclkc" |
| - GXM (S912) : "amlogic,meson-gxm-aoclkc" |
| followed by the common "amlogic,meson-gx-aoclkc" |
| |
| - #clock-cells: should be 1. |
| |
| Each clock is assigned an identifier and client nodes can use this identifier |
| to specify the clock which they consume. All available clocks are defined as |
| preprocessor macros in the dt-bindings/clock/gxbb-aoclkc.h header and can be |
| used in device tree sources. |
| |
| - #reset-cells: should be 1. |
| |
| Each reset is assigned an identifier and client nodes can use this identifier |
| to specify the reset which they consume. All available resets are defined as |
| preprocessor macros in the dt-bindings/reset/gxbb-aoclkc.h header and can be |
| used in device tree sources. |
| |
| Parent node should have the following properties : |
| - compatible: "amlogic,meson-gx-ao-sysctrl", "syscon", "simple-mfd" |
| - reg: base address and size of the AO system control register space. |
| |
| Example: AO Clock controller node: |
| |
| ao_sysctrl: sys-ctrl@0 { |
| compatible = "amlogic,meson-gx-ao-sysctrl", "syscon", "simple-mfd"; |
| reg = <0x0 0x0 0x0 0x100>; |
| |
| clkc_AO: clock-controller { |
| compatible = "amlogic,meson-gxbb-aoclkc", "amlogic,meson-gx-aoclkc"; |
| #clock-cells = <1>; |
| #reset-cells = <1>; |
| }; |
| }; |
| |
| Example: UART controller node that consumes the clock and reset generated |
| by the clock controller: |
| |
| uart_AO: serial@4c0 { |
| compatible = "amlogic,meson-uart"; |
| reg = <0x4c0 0x14>; |
| interrupts = <0 90 1>; |
| clocks = <&clkc_AO CLKID_AO_UART1>; |
| resets = <&clkc_AO RESET_AO_UART1>; |
| }; |