| EDT ft5x06 based Polytouch devices | |
| ---------------------------------- | |
| The edt-ft5x06 driver is useful for the EDT "Polytouch" family of capacitive | |
| touch screens. Note that it is *not* suitable for other devices based on the | |
| focaltec ft5x06 devices, since they contain vendor-specific firmware. In | |
| particular this driver is not suitable for the Nook tablet. | |
| It has been tested with the following devices: | |
| * EP0350M06 | |
| * EP0430M06 | |
| * EP0570M06 | |
| * EP0700M06 | |
| The driver allows configuration of the touch screen via a set of sysfs files: | |
| /sys/class/input/eventX/device/device/threshold: | |
| allows setting the "click"-threshold in the range from 20 to 80. | |
| /sys/class/input/eventX/device/device/gain: | |
| allows setting the sensitivity in the range from 0 to 31. Note that | |
| lower values indicate higher sensitivity. | |
| /sys/class/input/eventX/device/device/offset: | |
| allows setting the edge compensation in the range from 0 to 31. | |
| /sys/class/input/eventX/device/device/report_rate: | |
| allows setting the report rate in the range from 3 to 14. | |
| For debugging purposes the driver provides a few files in the debug | |
| filesystem (if available in the kernel). In /sys/kernel/debug/edt_ft5x06 | |
| you'll find the following files: | |
| num_x, num_y: | |
| (readonly) contains the number of sensor fields in X- and | |
| Y-direction. | |
| mode: | |
| allows switching the sensor between "factory mode" and "operation | |
| mode" by writing "1" or "0" to it. In factory mode (1) it is | |
| possible to get the raw data from the sensor. Note that in factory | |
| mode regular events don't get delivered and the options described | |
| above are unavailable. | |
| raw_data: | |
| contains num_x * num_y big endian 16 bit values describing the raw | |
| values for each sensor field. Note that each read() call on this | |
| files triggers a new readout. It is recommended to provide a buffer | |
| big enough to contain num_x * num_y * 2 bytes. | |
| Note that reading raw_data gives a I/O error when the device is not in factory | |
| mode. The same happens when reading/writing to the parameter files when the | |
| device is not in regular operation mode. |