dev-amdgpu: Fix interrupt handler address assignment
The interrupt handler's base address is sent via MMIO and must be
shifted by 8 bits to convert to a byte address. The current code is
shifting the MMIO dword first then assigning, resulting in the top 8
bits being shifted out.
This changeset fixes the issue by assigning the dword to the 64-bit
address first then shifting after. Similarly, the upper dword is cast to
a 64-bit value first before shifting.
This fixes some "fence fallback timeout" errors in the m5term output.
These timeouts become a problem because the driver will reset after a
few hundred of them, killing any running GPU applications as part of the
process.
Change-Id: I0beec313f533765c94063bcf4de8c65aacf2986b
Reviewed-on: https://gem5-review.googlesource.com/c/public/gem5/+/65092
Tested-by: kokoro <noreply+kokoro@google.com>
Reviewed-by: Matt Sinclair <mattdsinclair@gmail.com>
Maintainer: Matt Sinclair <mattdsinclair@gmail.com>
1 file changed